Mockup Erection Test at the Tower Saddle and Anchor Span
|
|
Cable
erection problems were expected to occur at the
pylon saddle and the splay band due to self-anchored
cable system and the difference between erection
and completed layout of the main cable. The mock-up
tests were performed prior to actual cable erection.
Through the tests, cable erection problems at the
saddle, lateral displacement and bending of the
wires inside the saddle, were identified and the
measures to deal with the problems were devised
and tested.
During cable erection, some of the wires at the
splay band was expected to show lateral displacement
and/or lift phenomena because of high flare angles
at the splay band. These displacements of the wires
disturbed the arrangement of wires at the splay
band. Mockup cable erection tests at the anchorage
were also carried out to find degree of displacements
of wires and appropriate measures to deal with these
problems. Through the test, the methods to arrange
wires at the splay bands were devised and tried.
|
|
|
|
|
|
|
¸ðÇü½ÃÇèÀü°æ
Mock-up Test
|
|
|
|
|
Æí½ò¸²Çö»ó
Lateral Displacement
|
|
|
|
|
¿ÍÀ̾î
Æ÷¸Ó ¹× Çü»óÀ¯Áö¿ë ¹êµå Wire-former and Shape-keeping
Band
|
|
|
|
|
|
|
|
| |
|
 |
|
|